Results for igt@xe_exec_basic@many-execqueues-bindexecqueue-rebind

Result: Pass

i915_display_info0 igt_runner0 results0.json results0-xe-load.json guc_logs0.tar i915_display_info_post_exec0 boot0 dmesg0

DetailValue
Duration 0.30 seconds
Hostname
shard-lnl-3
Igt-Version
IGT-Version: 2.3-g6a10d1136 (x86_64) (Linux: 6.19.0-rc7-lgci-xe-xe-4468-a13ec0c1edcbd6228+ x86_64)
Out
Using IGT_SRANDOM=1769747915 for randomisation
Opened device: /dev/dri/card0
Starting subtest: many-execqueues-bindexecqueue-rebind
Starting dynamic subtest: rcs0
Dynamic subtest rcs0: SUCCESS (0.078s)
Starting dynamic subtest: bcs0
Dynamic subtest bcs0: SUCCESS (0.056s)
Starting dynamic subtest: ccs0
Dynamic subtest ccs0: SUCCESS (0.055s)
Starting dynamic subtest: vcs0
Dynamic subtest vcs0: SUCCESS (0.057s)
Starting dynamic subtest: vecs0
Dynamic subtest vecs0: SUCCESS (0.052s)
Subtest many-execqueues-bindexecqueue-rebind: SUCCESS (0.305s)
Err
Starting subtest: many-execqueues-bindexecqueue-rebind
Starting dynamic subtest: rcs0
Dynamic subtest rcs0: SUCCESS (0.078s)
Starting dynamic subtest: bcs0
Dynamic subtest bcs0: SUCCESS (0.056s)
Starting dynamic subtest: ccs0
Dynamic subtest ccs0: SUCCESS (0.055s)
Starting dynamic subtest: vcs0
Dynamic subtest vcs0: SUCCESS (0.057s)
Starting dynamic subtest: vecs0
Dynamic subtest vecs0: SUCCESS (0.052s)
Subtest many-execqueues-bindexecqueue-rebind: SUCCESS (0.305s)
Dmesg
<6> [534.417701] Console: switching to colour dummy device 80x25
<6> [534.417999] [IGT] xe_exec_basic: executing
<6> [534.420197] [IGT] xe_exec_basic: starting subtest many-execqueues-bindexecqueue-rebind
<6> [534.420467] [IGT] xe_exec_basic: starting dynamic subtest rcs0
<7> [534.490776] xe 0000:00:02.0: [drm:intel_tc_port_reset_mode [xe]] Port E/TC#2: TC port mode reset (tbt-alt -> disconnected) pin assignment: - max lanes: 4
<7> [534.490773] xe 0000:00:02.0: [drm:intel_tc_port_reset_mode [xe]] Port F/TC#3: TC port mode reset (tbt-alt -> disconnected) pin assignment: - max lanes: 4
<7> [534.490782] xe 0000:00:02.0: [drm:intel_tc_port_reset_mode [xe]] Port D/TC#1: TC port mode reset (tbt-alt -> disconnected) pin assignment: - max lanes: 4
<6> [534.499286] [IGT] xe_exec_basic: finished subtest rcs0, SUCCESS
<6> [534.499682] [IGT] xe_exec_basic: starting dynamic subtest bcs0
<6> [534.556381] [IGT] xe_exec_basic: finished subtest bcs0, SUCCESS
<6> [534.557006] [IGT] xe_exec_basic: starting dynamic subtest ccs0
<6> [534.612665] [IGT] xe_exec_basic: finished subtest ccs0, SUCCESS
<6> [534.613082] [IGT] xe_exec_basic: starting dynamic subtest vcs0
<6> [534.670625] [IGT] xe_exec_basic: finished subtest vcs0, SUCCESS
<6> [534.671854] [IGT] xe_exec_basic: starting dynamic subtest vecs0
<6> [534.724682] [IGT] xe_exec_basic: finished subtest vecs0, SUCCESS
<6> [534.725164] [IGT] xe_exec_basic: finished subtest many-execqueues-bindexecqueue-rebind, SUCCESS
<7> [534.726248] xe 0000:00:02.0: [drm:intel_power_well_enable [xe]] enabling DC_off
<7> [534.727020] xe 0000:00:02.0: [drm:gen9_set_dc_state.part.0 [xe]] Setting DC state from 02 to 00
<7> [534.744009] xe 0000:00:02.0: [drm:drm_client_dev_restore] fbdev: ret=0
<6> [534.744419] [IGT] xe_exec_basic: exiting, ret=0
<6> [534.761842] Console: switching to colour frame buffer device 180x56
<7> [534.794882] xe 0000:00:02.0: [drm:intel_power_well_disable [xe]] disabling DC_off
<7> [534.795511] xe 0000:00:02.0: [drm:skl_enable_dc6 [xe]] Enabling DC6
<7> [534.796136] xe 0000:00:02.0: [drm:gen9_set_dc_state.part.0 [xe]] Setting DC state from 00 to 02
Created at 2026-01-30 05:20:42